通过Tornado/Python重新启动并恢复ZigBee传感器的启动配置

2024-06-02 08:06:27 发布

您现在位置:Python中文网/ 问答频道 /正文

我有个问题。一些传感器,通过传感器,传感器,自动装置等发送给家庭的传感器

我已经完成了一部分,我可以发送开/关/切换命令到ZigBee传感器。我已经遵循了this manual,这个命令在196页有描述。在

在我的项目中,我在python中有这样一个部分来设置要发送给传感器的正确数据包:

if command not in ['ON', 'OFF', 'TOGGLE']:
        raise tornado.web.HTTPError(404, "Unknown command: " + str(command))

    op_group = "70"
    op_code = "50"
    # *9999999999999999;70;50;;100260EB008060008000000D8#
    #                   70 50  100231AC00000000000008060008000101A9
    packet_meta = "*%s;%s;%s;%s;02%s%s600080000%s#"  # D8 i s the CRC who compute that?
    pkt_len = hextransform(16, 2)

    # Hexify the network ID
    netid = hextransform(int(nid), 16)
    # Hexify the sensor ID
    # TODO: - split sensor_id in ZTC sensor_id and endpoint!
    #       - ZTC sens ID is 2 bytes 
    #       - ZTC endpoint is 1 byte
#        sens_id = hextransform(int(sid) >> 8, 4)
#        end_point = hextransform(int(sid) & 0x0000FF, 2)


#        print("\nsens_id: '" + sens_id + "'\n")
#        print("\nendpoint: '" + end_point + "'\n")

    # TODO: - split sensor_id in ZTC sensor_id and clusterid!
    #       - ZTC sens ID is 2 bytes 
    #       - ZTC clusterid is 2 bytes
    sens_id = hextransform(int(sid) >> 16, 4)#elisa
    sens_id_little = invert2bytes(sens_id,0)
    cluster_id = hextransform(int(sid) & 0x00FFFF, 4)#elisa
    end_point = "08" #elisa

    if command == 'ON':
        cmd_data = "01"
    elif command == 'OFF':
        cmd_data = "00"
    elif command == 'TOGGLE':
        cmd_data = "02"

    packet = packet_meta % (netid, op_group, op_code, pkt_len, sens_id, end_point, cmd_data)
    packet = packet.upper()
    print("\t\t " + packet + "\n")

    ################ ELISA #########################################
    cmd_meta = "02%s000000000000080600080000%s" #elisa
    mycommand = cmd_meta % (sens_id_little, cmd_data) #elisa
    len_mycommand = len(mycommand)/2
    op_group_hex=0x70
    op_code_hex=0x50
    mynet_type ="ztc"

    cmdjson = packet2json(op_group_hex,op_code_hex, mycommand)
    #
    #
    #TODO : -write command into db  
    ts = datetime.datetime.now().isoformat()
    self.lock_tables("write", ['confcommands'])
self.db.execute("INSERT INTO confcommands (network_id, ntype, timestamp, command) \
                              VALUES (%s,%s,%s,%s)", nid, mynet_type, ts, cmdjson)
    self.unlock_tables();

现在,按照手册,我将添加重新启动命令,以重新启动传感器。然后还添加restore startup配置命令。在

所以我不知道这些命令在手册的什么地方。有好几个。然后,我看不清楚命令restart或restore startup配置的值。如果on/off/toggle有三个值(00、01、02),在这种情况下,手册没有说明为cmd_数据变量分配什么值,以便创建正确的数据包发送给传感器。在

我希望你能帮我,因为我不知道在哪里找这个。非常感谢你。在


Tags: 命令cmdiddatapacketgroup传感器sensor
2条回答

我不知道ZigBee技术,但根据您的文档,您可以尝试发送名为APSME-RESET.RequestAPSME-REST.Confirm的APS消息来进行平台重置,或者发送NLME-Reset.Request和{}来重置网络管理器

这段代码看起来像是在使用ZigBee OnOff集群(0x0006),因为命令与您的代码所做的匹配。因为ZigBee是little-endian,所以代码中的0600序列之一就是集群ID

基本集群(0x0000)支持单个命令0x00,该命令将设备重置为出厂默认值。小心使用此命令,因为它可能导致设备离开网络并返回其默认网络设置。在

我不知道ZCL(ZigBee集群库)集群和命令,您可以用来重新启动/重新启动设备。ZigBee传感器设计成可以运行数年而无需重启。在

要了解ZCL集群和命令的更多信息,可以从ZigBee Alliance下载ZigBee Cluster Library。在

为什么您的设备需要重新启动传感器?在